- Date
- 01/29/2018
- W/O
- 0679336
- Weather
- Dry
- Operator/Surveyor
- SANTIAGO OBREGON
- Sewer ID
- Z00334
- PipeID
- P08416
- Time
- 8:01 AM
- Certificate
- U-1014-06022541
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G7614
- Sewer Name
- A JOINT OUTFALL A - UNIT 3C
- City
- COMPTON
- Loc. details
- Parking Lot
- Location Code
- G
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 09
- Purpose
- Capital Improvement Program Assesment
- Project
- 20180129SHO_JOINT_OUTFALL_A_UNIT_3C
- Material
- RCP-CTL
- Shape
- Square
- Height
- 78 in.
- Width
- 78 in.
- Upstream MH
- A 0041
- Downstream MH
- A 0040
- Dir. of Survey
- Downstream
- Length Surveyed
- 1079.8 ft.
- Total Length
- 1079.8 ft.
- Structural Index
- 3
- Structural Quick
- 3100
- Structural Rating
- 3
- O&M Index
- 2
- O&M Quick
- 2200
- O&M Rating
- 4
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 7
Pipe schematic from manhole A 0041 to A 0040 Observation photos (7)

47 ft. - General Observation - POSSIBLE REBAR HANGING DOWN

82.3 ft. - General Observation - 100% TILES MISSING

130.3 ft. - General Observation - 50% TILES MISSING

233.3 ft. - Surface Aggregate Visible, from 12 to 04 o'clock, within 8 inches of joint: NO

591.3 ft. - Deposits Attached Other, 5 %of cross sectional area, at 11 o'clock, , within 8 inches of joint: NO - POSSIBLE RAGS CAUGHT ON BROKEN REBAR

732.2 ft. - General Observation - 50% TILES MISSING

795 ft. - Deposits Attached Other, 5 %of cross sectional area, from 09 to 10 o'clock, , within 8 inches of joint: NO - RAGS