- Date
- 12/27/2017
- W/O
- 679275
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00016
- PipeID
- P00068
- Time
- 10:14 PM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K5297
- Sewer Name
- 08 MAIN STREET TRUNK
- City
- GARDENA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 02
- Purpose
- Routine Assessment
- Project
- WO_679275_TV08116_JAN2018
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 08 0066
- Downstream MH
- 08 0065
- Dir. of Survey
- Downstream
- Length Surveyed
- 333 ft.
- Total Length
- 333.1 ft.
- Structural Index
- 3
- Structural Quick
- 4C3H
- Structural Rating
- 222
- O&M Index
- 2
- O&M Quick
- 3111
- O&M Rating
- 4
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 226
Pipe schematic from manhole 08 0066 to 08 0065 Observation photos (5)

3.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

38.9 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

201.5 ft. - Roots Fine Connection, from 08 to 10 o'clock

232 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

234 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start