Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 28, 2017, 08:32 AM
  • 08 0058_08 0057 _28122017_004312.mp4

Date
12/28/2017
W/O
679275
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00016
PipeID
P00060
Time
12:32 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5297
Sewer Name
08 MAIN STREET TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
04
Purpose
Routine Assessment
Project
WO_679275_TV08116_JAN2018
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
08 0058
Downstream MH
08 0057
Dir. of Survey
Downstream
Length Surveyed
287.5 ft.
Total Length
287.5 ft.
Structural Index
3
Structural Quick
3J00
Structural Rating
168
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
168
Pipe schematic from manhole 08 0058 to 08 0057
MH: 08 0058MH: 08 0057downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 08 00582.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start30.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"90.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"149.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"182 ft. MGO - General Observation - GASKET HANGING OUT, FROM 03 TO 05 O'CLOCK211.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"244.3 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: NO, 6"282.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish287.5 ft. AMH - Downstream Manhole, Survey Ends - 08 0057287.5 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK287.5 ft. MGO - General Observation - CAPPED LATERAL 3 O'CLOCK @ MH

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (15)

DistanceCodeObservation
0MWM
2.4CM
244.3TB
182MGOGASKET HANGING OUT, FROM 03 TO 05 O'CLOCK
30.6TF
149.8TFC
211.5TF
287.5AMH08 0057
0MWL
282.1CM
287.5MGOCONNECTION AT MH 9 O'CLOCK
0MGOCONNECTION AT MH 3 O'CLOCK
0AMH08 0058
287.5MGOCAPPED LATERAL 3 O'CLOCK @ MH
90.1TF

Properties (5)

additional_info
SC346771
custom_field_two
3
customer
LACSD
datetime
2017-12-28T00:32:52-08:00
sewer_category
Gravity