Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 27, 2017, 09:48 AM
  • 01 0344_01 0343A_12272017_014916.mp4

Date
12/27/2017
W/O
679271
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00215
PipeID
P00817
Time
1:48 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5295
Sewer Name
01 NADEAU TRUNK, SECTS 2&1
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
06
Purpose
Routine Assessment
Project
WO_679271_TV01126_JAN2018
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
01 0344
Downstream MH
01 0343A
Dir. of Survey
Downstream
Length Surveyed
324.9 ft.
Total Length
324.9 ft.
Structural Index
3
Structural Quick
3L00
Structural Rating
189
O&M Index
2
O&M Quick
2L00
O&M Rating
128
Overall Index
3
Overall Quick
Overall Rating
317
Pipe schematic from manhole 01 0344 to 01 0343A
MH: 01 0344MH: 01 0343Adownstream0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 03440 ft. MGO - General Observation - MAG COATING 70%0 ft. MWL - Water Level, 15 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start6.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start323.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish323.6 ft. MGO - General Observation - COCKROACHES IN MANHOLE323.6 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish324.9 ft. AMH - Downstream Manhole, Survey Ends - 01 0343A324.9 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    6.3 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
323.6DAGS
2DAGS
324.9AMH01 0343A
0MWM
6.3SAP
0AMH01 0344
323.6MGOCOCKROACHES IN MANHOLE
324.9MGOACTIVE CONNECTION AT MH 9 O'CLOCK
0MGOMAG COATING 70%
0MWL
323.6SAP

Properties (5)

additional_info
SC346432
custom_field_two
2
customer
LACSD
datetime
2017-12-27T01:48:52-08:00
sewer_category
Gravity