Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 23, 2018, 06:37 PM
  • 05 0028_05 0027_1232018_114649.mp4

Date
01/23/2018
W/O
0674047
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00431
PipeID
P05313
Time
10:37 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7608
Sewer Name
05 DISTRICT #5 MAIN TRUNK
City
TORRANCE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
27
Purpose
Routine Assessment
Project
20180123SHO_DISTRICT_5_MAIN_TRUNK
Material
RCP-CTL
Shape
Circular
Height
48 in.
Upstream MH
05 0028
Downstream MH
05 0027
Dir. of Survey
Downstream
Length Surveyed
451 ft.
Total Length
451 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
4
Pipe schematic from manhole 05 0028 to 05 0027
MH: 05 0028MH: 05 0027downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 45 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 11507.1 ft. MGO - General Observation - 90% MAG COAT INTACT58.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 16"415.7 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 8"451 ft. AMH - Downstream Manhole, Survey Ends - 1210

Observation photos (1)

  • General Observation - 90% MAG COAT INTACT

    7.1 ft. - General Observation - 90% MAG COAT INTACT

Observations (7)

DistanceCodeObservation
7.1MGO90% MAG COAT INTACT
451AMH1210
0MWM
58.8TFA
0MWL
0AMH1150
415.7TFA

Properties (4)

custom_field_three
90% MAG COAT INTACT
custom_field_two
4
customer
LACSD
datetime
2018-01-23T10:37:57-08:00