Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 23, 2018, 01:45 PM
  • Section#1_29 0780_29 0116__1232018__G6932.mp4

Date
01/23/2018
W/O
0685785
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00273
PipeID
P23905
Time
5:45 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6932
Sewer Name
29 33RD STREET SEWER
City
LONG BEACH
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
01
Purpose
Maintenance Related
Project
20180123MDM_33RD_STREET_SEWER
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
29 0780
Downstream MH
29 0116
Dir. of Survey
Downstream
Length Surveyed
101.2 ft.
Total Length
101.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2111
O&M Rating
3
Overall Index
2
Overall Quick
Overall Rating
3
Pipe schematic from manhole 29 0780 to 29 0116
MH: 29 0780MH: 29 0116downstream0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. AMH - Downstream Manhole, Survey Begins - 5:45AM0 ft. MGO - General Observation - MH CONN 9:00 ACTIVE0 ft. MWL - Water Level, 5 %of cross sectional area11 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 6", 6" - OPEN13.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN16.6 ft. TFD - Tap Factory Made Defective, at 09 o'clock, -, within 8 inches of joint: YES, 6" - OPEN-30% ROOTS16.6 ft. RFL - Roots Fine Lateral, from 08 to 10 o'clock - 5%36.7 ft. MGO - General Observation - 8" VCP96.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN100.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN101.2 ft. AMH - Upstream Manhole, Survey Ends - 6:00AM(CONCRETE PLUG)

Observation photos (3)

  • Tap Factory Made Defective, at 09 o'clock, -, within 8 inches of joint: YES, 6" - OPEN-30% ROOTS

    16.6 ft. - Tap Factory Made Defective, at 09 o'clock, -, within 8 inches of joint: YES, 6" - OPEN-30% ROOTS

  • General Observation - 8" VCP

    36.7 ft. - General Observation - 8" VCP

  • Upstream Manhole, Survey Ends - 6:00AM(CONCRETE PLUG)

    101.2 ft. - Upstream Manhole, Survey Ends - 6:00AM(CONCRETE PLUG)

Observations (12)

DistanceCodeObservation
36.7MGO8" VCP
96.4TFOPEN
0MWM
0AMH5:45AM
100.9TFOPEN
11TBOPEN
16.6TFDOPEN-30% ROOTS
0MGOMH CONN 9:00 ACTIVE
16.6RFL5%
13.1TFOPEN
0MWL
101.2AMH6:00AM(CONCRETE PLUG)

Properties (3)

additional_info
REVERSE INSPECTION
customer
LACSD
datetime
2018-01-23T05:45:00-08:00