Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 20, 2018, 09:20 AM
  • Section#8_H 0087_H 0086__1202018__G6928.mp4

Date
01/20/2018
W/O
0693963
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00165
PipeID
P10539
Time
1:20 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6928
Sewer Name
H JOINT OUTFALL H - UNIT 1F
City
HUNTINGTON PARK
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
07
Purpose
Capital Improvement Program Assesment
Project
20180119MDM_JOINT_OUTFALL_H_UNIT_1F
Material
Reinforced Concrete Pipe
Shape
Circular
Height
36 in.
Upstream MH
H 0087
Downstream MH
H 0086
Dir. of Survey
Downstream
Length Surveyed
765.2 ft.
Total Length
765.2 ft.
Structural Index
4
Structural Quick
5b4^
Structural Rating
1783
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
1783
Pipe schematic from manhole H 0087 to H 0086
MH: H 0087MH: H 0086downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 7:20AM2 ft. MGO - General Observation - MAG COAT 90% START 8:00 TO 4:002 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE2.3 ft. SRV - Surface Reinforcement Visible, from 08 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR39.2 ft. SRC - Surface Reinforcement Corroded, from 03 to 04 o'clock, within 8 inches of joint: YES, Start128.7 ft. SRV - Surface Reinforcement Visible, from 03 to 04 o'clock, within 8 inches of joint: NO - CIRCUM REBAR130.4 ft. SRV - Surface Reinforcement Visible, from 08 to 09 o'clock, within 8 inches of joint: YES, - CIRCUM REBAR258.4 ft. SRV - Surface Reinforcement Visible, from 08 to 09 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR283 ft. SRV - Surface Reinforcement Visible, from 08 to 09 o'clock, within 8 inches of joint: YES, Finish - CIRCUM REBAR331.8 ft. SRV - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR401.8 ft. SRV - Surface Reinforcement Visible, from 03 to 04 o'clock, within 8 inches of joint: NO - CIRCUM REBAR464.7 ft. SRC - Surface Reinforcement Corroded, from 03 to 04 o'clock, within 8 inches of joint: YES - CIRCUM REBAR607.3 ft. SRV - Surface Reinforcement Visible, from 08 to 09 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR688.9 ft. SRV - Surface Reinforcement Visible, from 08 to 09 o'clock, within 8 inches of joint: YES, Finish - CIRCUM REBAR755.2 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: NO - CIRCUM REBAR UNDER MAG COAT-POSSIBLE764.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - BLISTERING PEELING CONCRETE764.6 ft. SRC - Surface Reinforcement Corroded, from 03 to 04 o'clock, within 8 inches of joint: YES, Finish - CIRCUM REBAR764.6 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG764.6 ft. MGO - General Observation - 90% MAG COAT FINISH765.2 ft. AMH - Downstream Manhole, Survey Ends - 8:05AM

Observation photos (12)

  • General Observation - MAG COAT 90% START 8:00 TO 4:00

    2 ft. - General Observation - MAG COAT 90% START 8:00 TO 4:00

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

  • Surface Reinforcement Visible, from 08 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    2.3 ft. - Surface Reinforcement Visible, from 08 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

  • Surface Reinforcement Corroded, from 03 to 04 o'clock, within 8 inches of joint: YES, Start

    39.2 ft. - Surface Reinforcement Corroded, from 03 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 03 to 04 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    128.7 ft. - Surface Reinforcement Visible, from 03 to 04 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

  • Surface Reinforcement Visible, from 08 to 09 o'clock, within 8 inches of joint: YES,  - CIRCUM REBAR

    130.4 ft. - Surface Reinforcement Visible, from 08 to 09 o'clock, within 8 inches of joint: YES, - CIRCUM REBAR

  • Surface Reinforcement Visible, from 08 to 09 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

    258.4 ft. - Surface Reinforcement Visible, from 08 to 09 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

  • Surface Reinforcement Visible, from 03 to 04 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    401.8 ft. - Surface Reinforcement Visible, from 03 to 04 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

  • Surface Reinforcement Corroded, from 03 to 04 o'clock, within 8 inches of joint: YES - CIRCUM REBAR

    464.7 ft. - Surface Reinforcement Corroded, from 03 to 04 o'clock, within 8 inches of joint: YES - CIRCUM REBAR

  • Surface Reinforcement Visible, from 08 to 09 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

    607.3 ft. - Surface Reinforcement Visible, from 08 to 09 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

  • Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: NO - CIRCUM REBAR UNDER MAG COAT-POSSIBLE

    755.2 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: NO - CIRCUM REBAR UNDER MAG COAT-POSSIBLE

Observations (23)

DistanceCodeObservation
258.4SRVCIRCUM REBAR
0MWM
2MGOMAG COAT 90% START 8:00 TO 4:00
764.6SSSBLISTERING PEELING CONCRETE
401.8SRVCIRCUM REBAR
0MWL
755.2SRCCIRCUM REBAR UNDER MAG COAT-POSSIBLE
764.6SRCCIRCUM REBAR
607.3SRVCIRCUM REBAR
128.7SRVCIRCUM REBAR
764.6SAMSEVERE AGG
2SAMSEVERE AGG
464.7SRCCIRCUM REBAR
130.4SRVCIRCUM REBAR
331.8SRVCIRCUM REBAR
2.3SRVCIRCUM REBAR
688.9SRVCIRCUM REBAR
764.6MGO90% MAG COAT FINISH
2SSSBLISTERING PEELING CONCRETE
283SRVCIRCUM REBAR
39.2SRC
0AMH7:20AM
765.2AMH8:05AM

Properties (4)

custom_field_three
CIRCUM REBAR CORRODED- 90 % MAG COAT
custom_field_two
2
customer
LACSD
datetime