- Date
- 12/22/2017
- W/O
- 679275
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00016
- PipeID
- P00121
- Time
- 1:30 AM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K5291
- Sewer Name
- 08 MAIN STREET TRUNK
- City
- LOS ANGELES
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 01
- Purpose
- Routine Assessment
- Project
- WO_679275_TV08116_JAN2018
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 12 in.
- Width
- 12 in.
- Upstream MH
- 08 0093
- Downstream MH
- 08 0092
- Dir. of Survey
- Downstream
- Length Surveyed
- 319 ft.
- Total Length
- 319 ft.
- Structural Index
- 3
- Structural Quick
- 3K00
- Structural Rating
- 186
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 186
Pipe schematic from manhole 08 0093 to 08 0092