- Date
- 12/19/2017
- W/O
- 679304
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00283
- PipeID
- P04187
- Time
- 2:04 AM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K5282
- Sewer Name
- 02 MONTEBELLO INTERCEPTOR TRUNK, SECTS 1&2
- City
- MONTEBELLO
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 17
- Purpose
- Routine Assessment
- Project
- WO_679304_TV02213_JAN2018
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 30 in.
- Width
- 30 in.
- Upstream MH
- 02 1842
- Downstream MH
- 02 1841
- Dir. of Survey
- Downstream
- Length Surveyed
- 648.4 ft.
- Total Length
- 648.4 ft.
- Structural Index
- 3
- Structural Quick
- 3Y00
- Structural Rating
- 387
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 387
Pipe schematic from manhole 02 1842 to 02 1841 Observation photos (2)

5.6 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

16.6 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES