Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 18, 2017, 11:50 AM
  • 01 1215_01 1214_12182017_041916.mp4

Date
12/18/2017
W/O
678021
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00226
PipeID
P02127
Time
3:50 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5250
Sewer Name
01 WILCOX AVENUE TRUNK, EXTENSION #1
City
CUDAHY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
08
Purpose
Routine Assessment
Project
WO_678021_DISTRICT01_DEC2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 1215
Downstream MH
01 1214
Dir. of Survey
Downstream
Length Surveyed
101.4 ft.
Total Length
101.4 ft.
Structural Index
2
Structural Quick
2400
Structural Rating
8
O&M Index
2
O&M Quick
412C
O&M Rating
48
Overall Index
2
Overall Quick
Overall Rating
56
Pipe schematic from manhole 01 1215 to 01 1214
MH: 01 1215MH: 01 1214downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 12150 ft. MWL - Water Level, 20 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start39.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"42.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"73.5 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: NO, Start90.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"93 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"93 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: NO, Finish94.7 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - DEBRIS101.4 ft. AMH - Downstream Manhole, Survey Ends - 01 1214101.4 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish101.4 ft. MGO - General Observation - COCKROACHES IN MANHOLE101.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: NO, Start

    73.5 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: NO, Start

Observations (15)

DistanceCodeObservation
93TFC
0MWM
73.5CL
93CL
39.6TFC
90.5TFC
2DAGS
101.4AMH01 1214
101.4DSZ
0AMH01 1215
42.2TFC
101.4MGOCOCKROACHES IN MANHOLE
0MWL
94.7DSZDEBRIS
101.4DAGS

Properties (4)

additional_info
SC346422
custom_field_two
3
customer
LACSD
datetime
2017-12-18T03:50:59-08:00