Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 28, 2017, 08:22 AM
  • 02 1326_02 1325_28112017_002325.mp4

Date
11/28/2017
W/O
673943
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00238
PipeID
P03849
Time
12:22 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5052
Sewer Name
02 BELVEDERE TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
08
Purpose
Routine Assessment
Project
WO_673943_TV02329_DEC2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 1326
Downstream MH
02 1325
Dir. of Survey
Downstream
Length Surveyed
272.1 ft.
Total Length
272.2 ft.
Structural Index
3
Structural Quick
4B3G
Structural Rating
172
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
174
Pipe schematic from manhole 02 1326 to 02 1325
MH: 02 1326MH: 02 1325downstream0 ft. MWM - Water Mark, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 13260 ft. MWL - Water Level, 5 %of cross sectional area3.1 ft. CM - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start17.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"32.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"68.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"96.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"99.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"134.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"175.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"180.4 ft. RFB - Roots Fine Barrell, at 12 o'clock193 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"200.7 ft. CM - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish200.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start221.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"229.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"234.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"267.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish272.2 ft. AMH - Downstream Manhole, Survey Ends - 02 1325

Observation photos (3)

  • Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    3.1 ft. - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Barrell, at 12 o'clock

    180.4 ft. - Roots Fine Barrell, at 12 o'clock

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    200.7 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (20)

DistanceCodeObservation
180.4RFB
17.2TFC
267.7FM
3.1CM
0MWM
0AMH02 1326
234.2TFC
99.9TFC
229.1TFC
32.1TFC
200.7CM
272.2AMH02 1325
200.7FM
68.3TFC
134.7TF
175.5TFC
96.2TFC
221.6TFC
193TFC
0MWL

Properties (4)

additional_info
SC346281
custom_field_two
2
customer
LACSD
datetime