Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 5, 2017, 07:08 AM
  • 05 0704_05 0703 _04122017_230857.mp4

Date
12/04/2017
W/O
674254
Weather
Dry
Operator/Surveyor
K. ADAME
Sewer ID
Z00523
PipeID
P05936
Time
11:08 PM
Certificate
07009000
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4853
Sewer Name
05 SOUTH INGLEWOOD-ORANGE AVENUE TRUNK, EXTENSION #2
City
INGLEWOOD, CA
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
07
Purpose
Routine Assessment
Project
WO_674254_TV05106_DEC2017
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
05 0704
Downstream MH
05 0703
Dir. of Survey
Downstream
Length Surveyed
142.3 ft.
Total Length
142.3 ft.
Structural Index
4
Structural Quick
514A
Structural Rating
48
O&M Index
1
O&M Quick
1400
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
52
Pipe schematic from manhole 05 0704 to 05 0703
MH: 05 0704MH: 05 0703downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 07040 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area6.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES6.9 ft. BVV - Broken Void Visible, from 03 to 04 o'clock, within 8 inches of joint: YES10.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES12.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start41.1 ft. RFJ - Roots Fine Joint, from 09 to 03 o'clock, within 8 inches of joint: YES45.3 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 4"56.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish59.4 ft. RFJ - Roots Fine Joint, from 03 to 04 o'clock, within 8 inches of joint: YES59.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES69.1 ft. FM - Fracture Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES71.7 ft. CM - Crack Multiple, from 02 to 03 o'clock, within 8 inches of joint: YES75 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES78.2 ft. RFJ - Roots Fine Joint, from 08 to 11 o'clock, within 8 inches of joint: YES81.3 ft. FM - Fracture Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES81.3 ft. RFJ - Roots Fine Joint, from 04 to 08 o'clock, within 8 inches of joint: YES84.1 ft. FM - Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES87.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start98.1 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 4"130.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish136.3 ft. FM - Fracture Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES142.3 ft. AMH - Downstream Manhole, Survey Ends - 05 0703142.3 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK

Observation photos (16)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    6.9 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Broken Void Visible, from 03 to 04 o'clock, within 8 inches of joint: YES

    6.9 ft. - Broken Void Visible, from 03 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    10.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    12.9 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Joint, from 09 to 03 o'clock, within 8 inches of joint: YES

    41.1 ft. - Roots Fine Joint, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 03 to 04 o'clock, within 8 inches of joint: YES

    59.4 ft. - Roots Fine Joint, from 03 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    59.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES

    69.1 ft. - Fracture Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 02 to 03 o'clock, within 8 inches of joint: YES

    71.7 ft. - Crack Multiple, from 02 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    75 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 08 to 11 o'clock, within 8 inches of joint: YES

    78.2 ft. - Roots Fine Joint, from 08 to 11 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES

    81.3 ft. - Fracture Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 04 to 08 o'clock, within 8 inches of joint: YES

    81.3 ft. - Roots Fine Joint, from 04 to 08 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

    84.1 ft. - Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    87.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES

    136.3 ft. - Fracture Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES

Observations (25)

DistanceCodeObservation
59.4RFJ
84.1FM
6.9FM
0AMH05 0704
81.3FM
59.4FM
98.1TFC
130.1FM
81.3RFJ
142.3AMH05 0703
0MWM
136.3FM
71.7CM
0MWL
10.4FM
69.1FM
142.3MGOCONNECTION AT MH 3 O'CLOCK
6.9BVV
87.4FM
12.9FM
78.2RFJ
56.3FM
75FM
41.1RFJ
45.3TF