Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 24, 2015, 03:39 PM
  • 15 0656_15 0655_20151123_015907.mp4

Date
10/24/2015
W/O
531432
Weather
Dry
Operator/Surveyor
ERU
Sewer ID
Z00606
PipeID
P12928
Time
8:39 AM
Certificate
123456
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2287
Sewer Name
15 GRAND AVENUE TRUNK
City
SAN GABRIEL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
10
Purpose
Routine Assessment
Project
WO_531423_TV15027_OCT2015
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
15 0656
Downstream MH
15 0655
Dir. of Survey
Downstream
Length Surveyed
89.3 ft.
Total Length
89.3 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 15 0656 to 15 0655
MH: 15 0656MH: 15 0655downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01504.8 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start4.9 ft. MGO - General Observation - MAG COAT 30%29.4 ft. MGO - General Observation - UNMAPPED MANHOLE31.5 ft. MGO - General Observation - CONNECTION AT MH 3 0CLOCK ACTICE49.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"61.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"69.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"84.7 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish89.3 ft. MGO - General Observation - CONNECTION AT MH 9 OCLOCK ACTIVE89.3 ft. AMH - Downstream Manhole, Survey Ends - 0159

Observation photos (1)

  • Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    4.8 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
61.5TF
0MWM
4.8SAV
0MWL
89.3MGOCONNECTION AT MH 9 OCLOCK ACTIVE
31.5MGOCONNECTION AT MH 3 0CLOCK ACTICE
29.4MGOUNMAPPED MANHOLE
84.7SAV
69.2TFC
0AMH0150
4.9MGOMAG COAT 30%
89.3AMH0159
49.7TFA

Properties (5)

additional_info
SC205369
custom_field_two
3
customer
LACSD
datetime
2015-10-24T08:39:32-07:00
sewer_category
GRAVITY