Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 23, 2015, 11:07 AM
  • 15 0654_15 0653_20151123_032330.mp4

Date
11/23/2015
W/O
531432
Weather
Dry
Operator/Surveyor
ERU
Sewer ID
Z00606
PipeID
P12926
Time
3:07 AM
Certificate
123456
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2287
Sewer Name
15 GRAND AVENUE TRUNK
City
SAN GABRIEL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
10
Purpose
Routine Assessment
Project
WO_531423_TV15027_OCT2015
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
15 0654
Downstream MH
15 0653
Dir. of Survey
Downstream
Length Surveyed
305.4 ft.
Total Length
305.4 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 15 0654 to 15 0653
MH: 15 0654MH: 15 0653downstream0 ft. AMH - Upstream Manhole, Survey Begins - 03090 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area6.1 ft. MGO - General Observation - MAG COAT 30%6.1 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start6.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start16.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"44.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"53.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"96.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"109.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"155.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"185.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"200.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"203.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"251.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"254.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"300.7 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish300.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish305.3 ft. MGO - General Observation - CONNECTION AT MH 9 OCLOCK ACTIVE305.4 ft. AMH - Downstream Manhole, Survey Ends - 0324305.4 ft. MGO - General Observation - CONNECTION AT MH 3 OCLOCK

Observations (22)

DistanceCodeObservation
203.3TFC
251.9TFA
185.5TFA
300.7SAV
53.6TFA
96.5TFA
200.8TFC
155.3TFA
0AMH0309
300.8DAGS
305.3MGOCONNECTION AT MH 9 OCLOCK ACTIVE
305.4AMH0324
6.1MGOMAG COAT 30%
0MWM
6.1SAV
109.2TFA
6.1DAGS
44.8TFC
0MWL
305.4MGOCONNECTION AT MH 3 OCLOCK
16.9TFA
254.8TFA

Properties (5)

additional_info
SC205369
custom_field_two
3
customer
LACSD
datetime
2015-11-23T03:07:48-08:00
sewer_category
GRAVITY