Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 13, 2017, 12:42 PM
  • 18 0556_18 0714 _13112017_045312.mp4

Date
11/13/2017
W/O
635480
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00706
PipeID
P14565
Time
4:42 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5040
Sewer Name
18 SO WHITTIER OUTFALL TR, SECTS 1,2,3,&4
City
NORWALK
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
31
Purpose
Routine Assessment
Project
WO_635480_TV18053_NOV2017
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
42 in.
Width
42 in.
Upstream MH
18 0556
Downstream MH
18 0714
Dir. of Survey
Downstream
Length Surveyed
87.7 ft.
Total Length
87.7 ft.
Structural Index
2
Structural Quick
2B00
Structural Rating
30
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
30
Pipe schematic from manhole 18 0556 to 18 0714
MH: 18 0556MH: 18 0714downstream0 ft. MGO - General Observation - CONNECTION AT MH 4 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 18 05560 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area11.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start87.7 ft. AMH - Downstream Manhole, Survey Ends - 18 071487.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish87.7 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK

Observation photos (1)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    11.4 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
0MGOCONNECTION AT MH 4 O'CLOCK
0AMH18 0556
11.4SSS
87.7AMH18 0714
87.7SSS
87.7MGOCONNECTION AT MH 9 O'CLOCK
0MWM
0MWL

Properties (4)

additional_info
SC346265
custom_field_two
3
customer
LACSD
datetime
2017-11-13T04:42:00-08:00