Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 8, 2017, 05:52 AM
  • 18 0690_18 0689__07112017_030531.mp4

Date
11/07/2017
W/O
635480
Weather
Dry
Operator/Surveyor
JUAN B
Sewer ID
Z00706
PipeID
P14539
Time
9:52 PM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5166
Sewer Name
18 SO WHITTIER OUTFALL TR, SECTS 1,2,3,&4
City
CERRITOS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
34
Purpose
Routine Assessment
Project
WO_635480_TV18053_NOV2017
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
48 in.
Width
48 in.
Upstream MH
18 0690
Downstream MH
18 0689
Dir. of Survey
Downstream
Length Surveyed
439.9 ft.
Total Length
439.9 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
2
O&M Quick
4121
O&M Rating
7
Overall Index
2
Overall Quick
Overall Rating
9
Pipe schematic from manhole 18 0690 to 18 0689
MH: 18 0690MH: 18 0689downstream0 ft. MWL - Water Level, 50 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT 9 OC0 ft. AMH - Upstream Manhole, Survey Begins - 18 06904.9 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - MAG COATING4.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start4.9 ft. VC - Vermin Cockroach438.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish438.5 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish439.9 ft. AMH - Downstream Manhole, Survey Ends - 18 0689

Observation photos (2)

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - MAG COATING

    4.9 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - MAG COATING

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    4.9 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
4.9SSSMAG COATING
4.9DAGS
0MWL
438.5DAGS
0MWM
4.9VC
438.5SSS
0MGOCONNECTION AT 9 OC
439.9AMH18 0689
0AMH18 0690