Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 1, 2017, 11:58 AM
  • 05 0702_05 0701 _01122017_035911.mp4

Date
12/01/2017
W/O
674254
Weather
Dry
Operator/Surveyor
K. ADAME
Sewer ID
Z00523
PipeID
P05934
Time
3:58 AM
Certificate
07009000
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4851
Sewer Name
05 SOUTH INGLEWOOD-ORANGE AVENUE TRUNK, EXTENSION #2
City
INGLEWOOD, CA
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
07
Purpose
Routine Assessment
Project
WO_674254_TV05106_DEC2017
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
05 0702
Downstream MH
05 0701
Dir. of Survey
Downstream
Length Surveyed
264.8 ft.
Total Length
264.8 ft.
Structural Index
4
Structural Quick
5149
Structural Rating
47
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
4
Overall Quick
Overall Rating
48
Pipe schematic from manhole 05 0702 to 05 0701
MH: 05 0702MH: 05 0701downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 070224.3 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES27.6 ft. FM - Fracture Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES28.9 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 4"42.2 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES45.2 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES45.2 ft. RFJ - Roots Fine Joint, from 11 to 01 o'clock, within 8 inches of joint: YES51.5 ft. FM - Fracture Multiple, from 10 to 01 o'clock, within 8 inches of joint: YES54.5 ft. FM - Fracture Multiple, from 01 to 03 o'clock, within 8 inches of joint: YES63.5 ft. FM - Fracture Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES66.9 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES69.7 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES75.8 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES78.9 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start80.1 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 4"127.3 ft. B - Broken, from 08 to 02 o'clock, within 8 inches of joint: YES128.6 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: NO, 4"180 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 4"231.4 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 4"263.7 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish264.8 ft. AMH - Downstream Manhole, Survey Ends - 05 0701

Observation photos (13)

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    24.3 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES

    27.6 ft. - Fracture Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    42.2 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    45.2 ft. - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 11 to 01 o'clock, within 8 inches of joint: YES

    45.2 ft. - Roots Fine Joint, from 11 to 01 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 01 o'clock, within 8 inches of joint: YES

    51.5 ft. - Fracture Multiple, from 10 to 01 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 01 to 03 o'clock, within 8 inches of joint: YES

    54.5 ft. - Fracture Multiple, from 01 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES

    63.5 ft. - Fracture Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    66.9 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    69.7 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    75.8 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    78.9 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Broken, from 08 to 02 o'clock, within 8 inches of joint: YES

    127.3 ft. - Broken, from 08 to 02 o'clock, within 8 inches of joint: YES

Observations (23)

DistanceCodeObservation
63.5FM
42.2FM
263.7FM
231.4TF
127.3B
128.6TFA
0MWM
0MWL
78.9FM
80.1TF
0AMH05 0702
75.8FM
180TF
66.9FM
45.2FL
45.2RFJ
264.8AMH05 0701
27.6FM
54.5FM
24.3CM
51.5FM
69.7FM
28.9TF

Properties (5)

additional_info
SC349678
custom_field_two
3
customer
LACSD
datetime
2017-12-01T03:58:51-08:00
sewer_category
Gravity