Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 5, 2017, 10:18 AM
  • 05 0696_05 0695 _05122017_021921.mp4

Date
12/05/2017
W/O
674254
Weather
Dry
Operator/Surveyor
K. ADAME
Sewer ID
Z00523
PipeID
P05928
Time
2:18 AM
Certificate
07009000
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4853
Sewer Name
05 SOUTH INGLEWOOD-ORANGE AVENUE TRUNK, EXTENSION #2
City
INGLEWOOD, CA
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
07
Purpose
Routine Assessment
Project
WO_674254_TV05106_DEC2017
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
05 0696
Downstream MH
05 0695
Dir. of Survey
Downstream
Length Surveyed
266 ft.
Total Length
266 ft.
Structural Index
4
Structural Quick
4831
Structural Rating
35
O&M Index
2
O&M Quick
4131
O&M Rating
14
Overall Index
3
Overall Quick
Overall Rating
49
Pipe schematic from manhole 05 0696 to 05 0695
MH: 05 0696MH: 05 0695downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 06960 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area20.9 ft. FM - Fracture Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES20.9 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES24 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES30.4 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES33.2 ft. FM - Fracture Multiple, from 01 to 02 o'clock, within 8 inches of joint: YES36.3 ft. FM - Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES39.4 ft. FM - Fracture Multiple, from 09 to 01 o'clock, within 8 inches of joint: YES40.6 ft. RBL - Roots Ball Lateral, at 09 o'clock, 85 %40.6 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: YES, 4"41.8 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES44.9 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES47.9 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start92.2 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: YES, 4"92.2 ft. RML - Roots Medium Lateral, at 09 o'clock, 50 %, within 8 inches of joint: YES117.9 ft. RFJ - Roots Fine Joint, from 02 to 04 o'clock, within 8 inches of joint: YES126.9 ft. RFJ - Roots Fine Joint, from 03 to 04 o'clock, within 8 inches of joint: YES139.3 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES140.8 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: YES, 4"148.2 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES160.9 ft. RFJ - Roots Fine Joint, from 09 to 03 o'clock, within 8 inches of joint: YES169.8 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start192.4 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: YES, 4"241.1 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: YES, 4"263.9 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish263.9 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish266 ft. AMH - Downstream Manhole, Survey Ends - 05 0695

Observation photos (18)

  • Fracture Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

    20.9 ft. - Fracture Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES

    20.9 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    24 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    30.4 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 01 to 02 o'clock, within 8 inches of joint: YES

    33.2 ft. - Fracture Multiple, from 01 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

    36.3 ft. - Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 01 o'clock, within 8 inches of joint: YES

    39.4 ft. - Fracture Multiple, from 09 to 01 o'clock, within 8 inches of joint: YES

  • Roots Ball Lateral, at 09 o'clock, 85 %

    40.6 ft. - Roots Ball Lateral, at 09 o'clock, 85 %

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    41.8 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    44.9 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    47.9 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Roots Medium Lateral, at 09 o'clock, 50 %, within 8 inches of joint: YES

    92.2 ft. - Roots Medium Lateral, at 09 o'clock, 50 %, within 8 inches of joint: YES

  • Roots Fine Joint, from 02 to 04 o'clock, within 8 inches of joint: YES

    117.9 ft. - Roots Fine Joint, from 02 to 04 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 03 to 04 o'clock, within 8 inches of joint: YES

    126.9 ft. - Roots Fine Joint, from 03 to 04 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES

    139.3 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES

    148.2 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 09 to 03 o'clock, within 8 inches of joint: YES

    160.9 ft. - Roots Fine Joint, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    169.8 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (29)

DistanceCodeObservation
92.2TF
139.3RFJ
140.8TF
20.9FM
92.2RML
169.8RFJ
192.4TF
266AMH05 0695
39.4FM
47.9FM
0AMH05 0696
24FM
20.9RFJ
44.9FL
117.9RFJ
263.9RFJ
126.9RFJ
160.9RFJ
30.4FM
36.3FM
241.1TF
0MWM
40.6RBL
148.2RFJ
40.6TF
33.2FM
41.8FM
263.9FM
0MWL

Properties (5)

additional_info
SC349680
custom_field_two
3
customer
LACSD
datetime
2017-12-05T02:18:40-08:00
sewer_category
Gravity