Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 8, 2017, 06:29 AM
  • 18 1227_18 1226 _07122017_222943.mp4

Date
12/07/2017
W/O
673978
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01143
PipeID
P25607
Time
10:29 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5267
Sewer Name
18 WORSHAM CREEK REPLACEMENT TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
11
Purpose
Routine Assessment
Project
WO_673978_TV18077_DEC2017
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
18 1227
Downstream MH
18 1226
Dir. of Survey
Downstream
Length Surveyed
380 ft.
Total Length
380 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 18 1227 to 18 1226
MH: 18 1227MH: 18 1226downstream0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 18 12270 ft. MWL - Water Level, 10 %of cross sectional area28.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"76.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"118.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"142.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"143.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"151.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"153 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"202.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"204.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"233.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"234.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"267.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"273.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"283.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"288.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"298.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"322.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"331.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"369.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"380 ft. AMH - Downstream Manhole, Survey Ends - 18 1226

Observations (24)

DistanceCodeObservation
153TF
0MWM
283.1TF
0MGOCONNECTION AT MH 3 O'CLOCK
273.2TFC
28.2TF
380AMH18 1226
298.6TF
288.5TFA
204.3TFC
322.8TF
202.7TF
234.9TF
151.4TFC
369.6TF
233.5TF
0AMH18 1227
143.8TF
118.4TF
267.2TF
331.7TF
76.4TF
142.2TF
0MWL

Properties (6)

additional_info
SC346294
custom_field_two
4
customer
LACSD
datetime
2017-12-07T22:29:15-08:00
sewer_category
Gravity
year_laid
38658