Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 12, 2017, 08:02 AM
  • 15 0608_15 0607_12102017_010239.mp4

Date
10/12/2017
W/O
663065
Weather
Dry
Operator/Surveyor
K. ADAME
Sewer ID
Z00601
PipeID
P12540
Time
1:02 AM
Certificate
07009000
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4828
Sewer Name
15 DOUBLE AVENUE TRUNK
City
TEMPLE CITY, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
11
Purpose
Routine Assessment
Project
WO_663065_TV15183_OCT2017
Material
NRCP
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
15 0607
Downstream MH
15 0607A
Dir. of Survey
Upstream
Length Surveyed
154.1 ft.
Total Length
154.1 ft.
Structural Index
2
Structural Quick
3124
Structural Rating
11
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
11
Pipe schematic from manhole 15 0607 to 15 0607A
MH: 15 0607MH: 15 0607Aupstream0 ft. AMH - Upstream Manhole, Survey Ends - 15 0607A11.1 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES50.1 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 6"79.8 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES85.9 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"100.7 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES124.6 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES127.9 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 6"148 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES154.1 ft. MWM - Water Mark, 20 %of cross sectional area154.1 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK154.1 ft. MWL - Water Level, 5 %of cross sectional area154.1 ft. AMH - Downstream Manhole, Survey Begins - 15 0607

Observation photos (5)

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    6.1 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    29.5 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    53.4 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    74.3 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    143 ft. - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES

Observations (13)

DistanceCodeObservation
0MWM
154.1AMH15 0607A
6.1CL
29.5CL
53.4CL
0MGOCONNECTION AT MH 3 O'CLOCK
74.3CL
143FL
26.2TF
0MWL
104TF
0AMH15 0607
68.2TF

Properties (5)

additional_info
SC353079
custom_field_two
4
customer
LACSD
datetime
2017-10-12T01:02:30-07:00
sewer_category
Gravity