- Date
- 10/12/2017
- W/O
- 663065
- Weather
- Dry
- Operator/Surveyor
- K. ADAME
- Sewer ID
- Z00601
- PipeID
- P12537
- Time
- 1:34 AM
- Certificate
- 07009000
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K4828
- Sewer Name
- 15 DOUBLE AVENUE TRUNK
- City
- TEMPLE CITY, CA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 11
- Purpose
- Routine Assessment
- Project
- WO_663065_TV15183_OCT2017
- Material
- NRCP
- Shape
- Circular
- Height
- 10 in.
- Width
- 10 in.
- Upstream MH
- 15 0605
- Downstream MH
- 15 0604
- Dir. of Survey
- Downstream
- Length Surveyed
- 308.7 ft.
- Total Length
- 308.7 ft.
- Structural Index
- 3
- Structural Quick
- 4132
- Structural Rating
- 10
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 10
Pipe schematic from manhole 15 0605 to 15 0604 Observation photos (3)

33.6 ft. - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES

63.7 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

299.3 ft. - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES