05 1545_05 1544A_12112017_034733.mp4
05 1545_05 1544A_12112017_042804.mp4
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE UNDER MAG COAT
8 ft. - Surface Spalling, from 11 to 01 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE
8 ft. - General Observation - 18" RCP
17.6 ft. - Surface Spalling, from 11 to 01 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC
20.8 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE
24.5 ft. - Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: YES - SEVERE AGG SPORATIC
29.5 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC
45.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - PEELING CONCRETE
64 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE
76.5 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG
121.6 ft. - Surface Reinforcement Visible, from 08 to 10 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR
129.6 ft. - Surface Reinforcement Visible, from 08 to 09 o'clock, within 8 inches of joint: YES - CIRCUM REBAR
235.6 ft. - Surface Missing Wall, from 11 to 01 o'clock, within 8 inches of joint: YES - POSSIBLE MISSING WALL FILLED WITH DUCT TAPE
235.6 ft. - Surface Missing Wall, from 11 to 01 o'clock, within 8 inches of joint: YES - POSSIBLE REPAIR(APPOX 6" X3"
282.4 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR
283.2 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO, Start - LONG REBAR
298.7 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR
304.6 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: YES - LONG REBAR
323.3 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR
327.4 ft. - Deposits Settled Other, 5 %of cross sectional area, from 06 to 08 o'clock, , within 8 inches of joint: YES - PEELING CONCRETE
613 ft. - Surface Reinforcement Visible, from 02 to 04 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR
637.2 ft. - Deposits Attached Grease, 15 %of cross sectional area, from 08 to 09 o'clock, , within 8 inches of joint: NO
| Distance | Code | Observation |
|---|---|---|
| 638.8 | AMH | 5:00AM |
| 121.6 | SRV | CIRCUM REBAR |
| 64 | SSS | PEELING CONCRETE |
| 124.8 | SRV | CIRCUM REBAR |
| 235.6 | SMW | POSSIBLE MISSING WALL FILLED WITH DUCT TAPE |
| 2 | SSS | BLISTERING PEELING CONCRETE UNDER MAG COAT |
| 282.4 | SRV | CIRCUM REBAR |
| 290.2 | SRV | CIRCUM REBAR |
| 0 | MWL | — |
| 613 | SRV | CIRCUM REBAR |
| 294.2 | TB | Open |
| 29.5 | SAV | SEVERE AGG SPORATIC |
| 17.6 | SSS | SEVERE AGG SPORATIC |
| 235.6 | SMW | POSSIBLE REPAIR(APPOX 6" X3" |
| 76.5 | SAV | SEVERE AGG |
| 8 | SSS | BLISTERING CONCRETE |
| 283.2 | SRV | LONG REBAR |
| 0 | MGO | Conn. @ Mh, 9 O' Clock. Active |
| 290.2 | SRV | LONG REBAR |
| 129.6 | SRV | CIRCUM REBAR |
| 616.4 | SRV | CIRCUM REBAR |
| 294.2 | DAE | — |
| 45.1 | SSS | PEELING CONCRETE |
| 638.5 | SAV | SEVERE AGG |
| 304.6 | SRV | LONG REBAR |
| 0 | AMH | 4:50AM |
| 298.7 | SRV | CIRCUM REBAR |
| 638.5 | SSS | BLISTERING PEELING CONCRETE |
| 323.3 | SRV | CIRCUM REBAR |
| 24.5 | SAV | SEVERE AGG SPORATIC |
| 0 | MWM | — |
| 8 | MGO | 18" RCP |
| 637.2 | DAGS | — |
| 304.6 | SRV | CIRCUM REBAR |
| 327.4 | DSZ | PEELING CONCRETE |
| 20.8 | SSS | PEELING CONCRETE |
| 638.5 | MGO | Conn. @ Mh, 3 O' Clock. Active |
| 328.4 | SRV | CIRCUM REBAR |