Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 30, 2017, 07:20 AM
  • 02 1762_02 1761 _29112017_232055.mp4

Date
11/29/2017
W/O
674573
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00254
PipeID
P04109
Time
11:20 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5055
Sewer Name
02 DOWNEY-BELLFLOWER EXTENSION TRUNK
City
PICO RIVERA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
15
Purpose
Routine Assessment
Project
WO_674573_TV02052_DEC2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
02 1762
Downstream MH
02 1761
Dir. of Survey
Downstream
Length Surveyed
261.4 ft.
Total Length
261.4 ft.
Structural Index
3
Structural Quick
3I00
Structural Rating
153
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
3
Overall Quick
Overall Rating
154
Pipe schematic from manhole 02 1762 to 02 1761
MH: 02 1762MH: 02 1761downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 17624.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES10.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start13.6 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"73.8 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"145.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"151.9 ft. RFJ - Roots Fine Joint, from 03 to 04 o'clock, within 8 inches of joint: YES195.4 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"244.7 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"259.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish261.4 ft. MGO - General Observation - CAPPED LATERAL 3 O'CLOCK @ MH261.4 ft. AMH - Downstream Manhole, Survey Ends - 02 1761

Observation photos (3)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    4.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    10.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Joint, from 03 to 04 o'clock, within 8 inches of joint: YES

    151.9 ft. - Roots Fine Joint, from 03 to 04 o'clock, within 8 inches of joint: YES

Observations (14)

DistanceCodeObservation
145.1TF
0MWL
73.8TFA
261.4MGOCAPPED LATERAL 3 O'CLOCK @ MH
259.5CM
13.6TF
261.4AMH02 1761
195.4TF
244.7TF
0MWM
0AMH02 1762
151.9RFJ
4.8CM
10.8CM

Properties (4)

additional_info
SC346284
custom_field_two
3
customer
LACSD
datetime