Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 27, 2017, 11:13 AM
  • 02 1440_02 1439_27112017_033107.mp4

Date
11/27/2017
W/O
668676
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00307
PipeID
P04679
Time
3:13 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5049
Sewer Name
02 TRACT #5445 TRUNK
City
COMMERCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Routine Assessment
Project
WO_668676_TV02302_NOV2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
02 1440
Downstream MH
02 1439
Dir. of Survey
Downstream
Length Surveyed
362.3 ft.
Total Length
362.3 ft.
Structural Index
3
Structural Quick
3I23
Structural Rating
153
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
155
Pipe schematic from manhole 02 1440 to 02 1439
MH: 02 1440MH: 02 1439downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 14404.1 ft. CM - Crack Multiple, from 07 to 02 o'clock, within 8 inches of joint: YES34.4 ft. FC - Fracture Circumferential, from 07 to 10 o'clock, within 8 inches of joint: YES96.7 ft. CM - Crack Multiple, from 08 to 05 o'clock, within 8 inches of joint: YES116.5 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start121.2 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish121.2 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start141.5 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"143 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"161.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start161.5 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish215.5 ft. TSI - Tap Saddle Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 1", 6"255 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"267.6 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"356.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish362.3 ft. AMH - Downstream Manhole, Survey Ends - 02 1439

Observation photos (7)

  • Crack Multiple, from 07 to 02 o'clock, within 8 inches of joint: YES

    4.1 ft. - Crack Multiple, from 07 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Circumferential, from 07 to 10 o'clock, within 8 inches of joint: YES

    34.4 ft. - Fracture Circumferential, from 07 to 10 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 05 o'clock, within 8 inches of joint: YES

    96.7 ft. - Crack Multiple, from 08 to 05 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    116.5 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    121.2 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    161.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Saddle Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 1", 6"

    215.5 ft. - Tap Saddle Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 1", 6"

Observations (18)

DistanceCodeObservation
96.7CM
0MWM
121.2CL
143TFC
267.6TB
255TFC
34.4FC
0MWL
161.5CM
356.4CM
116.5CL
121.2CM
215.5TSI
141.5TB
4.1CM
362.3AMH02 1439
0AMH02 1440
161.5CM

Properties (4)

additional_info
SC346278
custom_field_two
3
customer
LACSD
datetime
2017-11-27T03:13:17-08:00