Section#3_08 0005_08 0004__12212017__G6889.mp4
2 ft. - General Observation - MAG COAT 80% START
2 ft. - General Observation - 100% MISSING TILES START 10:00 TO 2:00
2 ft. - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG AREAS OF MISSING TILES
15.4 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO, Start - LONG & CIRCUM REBAR UNDER MAG COAT
74.9 ft. - General Observation - 1 ROW TILES
93.4 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR CORRODED
126.6 ft. - General Observation - 1 ROW TILES IN PLACE
175.5 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - LONG % CIRCUM REBAR
246.8 ft. - General Observation - 33" RCP-CTL
| Distance | Code | Observation |
|---|---|---|
| 15.4 | SRC | LONG & CIRCUM REBAR UNDER MAG COAT |
| 275.2 | MGO | 100% MISSING TILES FINISH |
| 2 | MGO | MAG COAT 80% START |
| 235.6 | TF | ACTIVE |
| 74.9 | MGO | 1 ROW TILES |
| 0 | MWL | — |
| 126.6 | MGO | 1 ROW TILES IN PLACE |
| 246.8 | MGO | 33" RCP-CTL |
| 2 | MGO | 100% MISSING TILES START 10:00 TO 2:00 |
| 275.2 | MGO | MAG COST 80% FINISH |
| 0 | AMH | 3:50AM |
| 175.5 | SRC | LONG % CIRCUM REBAR |
| 93.4 | SRC | CIRCUM REBAR CORRODED |
| 2 | SAM | SEVERE AGG AREAS OF MISSING TILES |
| 275.2 | SAM | SEVERE AGG |
| 275.5 | AMH | 4:30AM |
| 275.2 | SRC | LONG & CIRCUM REBAR |
| 0 | MWM | — |