- Date
- 10/20/2016
- W/O
- 597387
- Weather
- Dry
- Operator/Surveyor
- J. HARTOOG
- Sewer ID
- Z00290
- PipeID
- P04529
- Time
- 4:05 AM
- Certificate
- U-507-3386
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K3744
- Sewer Name
- 02 MONTEREY PARK EXTENSION RELIEF TRUNK
- City
- MONTEREY PARK, CA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 06
- Purpose
- Routine Assessment
- Project
- WO_597387_TV02101_OCT2016
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 18 in.
- Width
- 18 in.
- Upstream MH
- 02 2278
- Downstream MH
- 02 2277
- Dir. of Survey
- Downstream
- Length Surveyed
- 441.8 ft.
- Total Length
- 441.8 ft.
- Structural Index
- 3
- Structural Quick
- 3222
- Structural Rating
- 10
- O&M Index
- 2
- O&M Quick
- 2Q00
- O&M Rating
- 176
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 186
Pipe schematic from manhole 02 2278 to 02 2277 Observation photos (5)

2.5 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

254.3 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

266.8 ft. - Crack Multiple, from 12 to 01 o'clock, within 8 inches of joint: YES

326 ft. - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

337.8 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES