- Date
- 12/15/2015
- W/O
- 521098
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00238
- PipeID
- P03791
- Time
- 1:51 AM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K2850
- Sewer Name
- 02 BELVEDERE TRUNK
- City
- COMMERCE
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 12
- Purpose
- Routine Assessment
- Project
- WO_521098_TV02329_AUG2015
- Sewer Type
- GRAVITY
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 24 in.
- Upstream MH
- 02 1277
- Downstream MH
- 02 1276
- Dir. of Survey
- Downstream
- Length Surveyed
- 359.1 ft.
- Total Length
- 359.1 ft.
- Structural Index
- 3
- Structural Quick
- 3M00
- Structural Rating
- 216
- O&M Index
- 2
- O&M Quick
- 2[00
- O&M Rating
- 284
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 500
Pipe schematic from manhole 02 1277 to 02 1276 Observation photos (2)

2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

249.4 ft. - Hole, at 12 o'clock, within 8 inches of joint: YES