- Date
- 09/29/2017
- W/O
- 658185
- Weather
- Dry
- Operator/Surveyor
- CORTEZ ESTEBAN
- Sewer ID
- Z00156
- PipeID
- P10003
- Time
- 12:29 AM
- Certificate
- U-209-8148
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K4946
- Sewer Name
- D JOINT OUTFALL D - UNIT 6
- City
- LAWNDALE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 17
- Purpose
- Routine Assessment
- Project
- WO_658185_TV05172_SEP2017
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 33 in.
- Width
- 33 in.
- Upstream MH
- D 0097
- Downstream MH
- D 0096
- Dir. of Survey
- Downstream
- Length Surveyed
- 313.8 ft.
- Total Length
- 313.8 ft.
- Structural Index
- 3
- Structural Quick
- 3200
- Structural Rating
- 6
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 8
Pipe schematic from manhole D 0097 to D 0096 Observation photos (3)

8.7 ft. - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

56.8 ft. - Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

304.4 ft. - Tap Break-In Intruding, at 02 o'clock, -, -, within 8 inches of joint: YES, 6", 1"