Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 12, 2015, 12:18 PM
  • 18 0804_18 0803_20151112_043301.mp4

Date
11/12/2015
W/O
531105
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00706
PipeID
P14664
Time
4:18 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2860
Sewer Name
18 SO WHITTIER OUTFALL TR, SECTS 1,2,3,&4
City
WHITTIER, CA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
14
Purpose
Routine Assessment
Project
WO_531105_TV18114_OCT2015
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Upstream MH
18 0804
Downstream MH
18 0803
Dir. of Survey
Downstream
Length Surveyed
349.2 ft.
Total Length
349.2 ft.
Structural Index
3
Structural Quick
423D
Structural Rating
77
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
77
Pipe schematic from manhole 18 0804 to 18 0803
MH: 18 0804MH: 18 0803downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 0804 (0418)0 ft. MGO - General Observation - LATERAL AT MH 3 0CLOCK0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area13.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start128 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish128.7 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start344.9 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish349 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK349.1 ft. MGO - General Observation - LATERAL AT MH 3 0CLOCK349.2 ft. AMH - Downstream Manhole, Survey Ends - 18 0803 432)

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    13.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

    128.7 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
344.9FM
349.1MGOLATERAL AT MH 3 0CLOCK
349MGOLATERAL AT MH 9 OCLOCK
13.4CM
0AMH18 0804 (0418)
349.2AMH18 0803 432)
128.7FM
0MGOLATERAL AT MH 3 0CLOCK
128CM
0MWM
0MWL

Properties (5)

additional_info
SC205625
custom_field_two
2
customer
LACSD
datetime
2015-11-12T04:18:05-08:00
sewer_category
GRAVITY