Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 12, 2015, 11:20 AM
  • 18 0810_18 0809_20151112_032819.mp4

Date
11/12/2015
W/O
531105
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00706
PipeID
P14671
Time
3:20 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2860
Sewer Name
18 SO WHITTIER OUTFALL TR, SECTS 1,2,3,&4
City
WHITTIER, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
14
Purpose
Routine Assessment
Project
WO_531105_TV18114_OCT2015
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Upstream MH
18 0809
Downstream MH
18 0810
Dir. of Survey
Upstream
Length Surveyed
165.5 ft.
Total Length
165.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2111
O&M Rating
3
Overall Index
2
Overall Quick
Overall Rating
3
Pipe schematic from manhole 18 0809 to 18 0810
MH: 18 0809MH: 18 0810upstream0 ft. AMH - Upstream Manhole, Survey Ends - 18 0810 (0327 )3.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Finish153.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start162.4 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 4"165.5 ft. MWL - Water Level, 10 %of cross sectional area165.5 ft. MWM - Water Mark, 20 %of cross sectional area165.5 ft. AMH - Downstream Manhole, Survey Begins - 18 0809 (0320)165.5 ft. VC - Vermin Cockroach

Observations (8)

DistanceCodeObservation
165.5AMH18 0810 (0327 )
12.3DAGS
0MWL
0MWM
0AMH18 0809 (0320)
0VC
161.9DAGS
3.1TFA

Properties (5)

additional_info
SC205625
custom_field_two
4
customer
LACSD
datetime
2015-11-12T03:20:07-08:00
sewer_category
GRAVITY