Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 24, 2017, 08:53 AM
  • H 1510_H 1509 _241017_011323.mp4

Date
10/24/2017
W/O
668649
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01206
PipeID
P16470
Time
1:53 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5036
Sewer Name
H JOINT OUTFALL H - UNIT 8M RELIEF
City
WEST COVINA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
31
Purpose
Routine Assessment
Project
WO_668649_TV22094_NOV2017
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
H 1510
Downstream MH
H 1509
Dir. of Survey
Downstream
Length Surveyed
566.2 ft.
Total Length
566.2 ft.
Structural Index
3
Structural Quick
3V2V
Structural Rating
565
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
565
Pipe schematic from manhole H 1510 to H 1509
MH: H 1510MH: H 1509downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 15100 ft. MWM - Water Mark, 35 %of cross sectional area2.4 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start566.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish566.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish566.2 ft. AMH - Downstream Manhole, Survey Ends - H 1509

Observation photos (2)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.4 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.4 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
2.4SAP
0MWL
2.4SSS
566.2SAP
0AMHH 1510
0MWM
566.2SSS
566.2AMHH 1509

Properties (6)

additional_info
SC346199
custom_field_two
3
customer
LACSD
datetime
2017-10-24T01:53:52-07:00
sewer_category
Gravity
year_laid
30047