Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 6, 2017, 05:57 AM
  • 05 0899_05 0898 _05102017_225808.mp4

Date
10/05/2017
W/O
663255
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00512
PipeID
P06129
Time
10:57 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5007
Sewer Name
05 RAYMOND AVENUE TRUNK
City
HAWTHRONE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
13
Purpose
Routine Assessment
Project
WO_663255_TV05204_OCT2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
05 0899
Downstream MH
05 0898
Dir. of Survey
Downstream
Length Surveyed
318.3 ft.
Total Length
318.3 ft.
Structural Index
3
Structural Quick
5141
Structural Rating
201
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
203
Pipe schematic from manhole 05 0899 to 05 0898
MH: 05 0899MH: 05 0898downstream0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 05 08990 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area4.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start20.6 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 6", 6" - FRACTURE68.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"81.5 ft. FS - Fracture Spiral, from 08 to 02 o'clock, within 8 inches of joint: YES - POSSIBLY BROKEN WITH SOIL81.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"84 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"117.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"126.9 ft. B - Broken, from 12 to 04 o'clock, within 8 inches of joint: YES - POSSIBLE SOIL VISIBLE128.7 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"147.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"162.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"174.5 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"208.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"222.7 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"238.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"258.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"276 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES289.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"291.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"302 ft. TSA - Tap Saddle Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"313.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish313.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES318.3 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK, ACTIVE318.3 ft. AMH - Downstream Manhole, Survey Ends - 05 0898318.3 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK, ACTIVE

Observation photos (6)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Spiral, from 08 to 02 o'clock, within 8 inches of joint: YES - POSSIBLY BROKEN WITH SOIL

    81.5 ft. - Fracture Spiral, from 08 to 02 o'clock, within 8 inches of joint: YES - POSSIBLY BROKEN WITH SOIL

  • Broken, from 12 to 04 o'clock, within 8 inches of joint: YES - POSSIBLE SOIL VISIBLE

    126.9 ft. - Broken, from 12 to 04 o'clock, within 8 inches of joint: YES - POSSIBLE SOIL VISIBLE

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    276 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Tap Saddle Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"

    302 ft. - Tap Saddle Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    313.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (29)

DistanceCodeObservation
68.6TFC
81.5FSPOSSIBLY BROKEN WITH SOIL
4.9CM
318.3MGOCONNECTION AT MH 3 O'CLOCK, ACTIVE
313.4CM
0MGOCONNECTION AT MH 3 O'CLOCK
126.9BPOSSIBLE SOIL VISIBLE
302TSA
117.1TFC
313.4FM
174.5TB
81.5TF
20.6TFDFRACTURE
318.3AMH05 0898
289.8TF
84TF
222.7TB
0AMH05 0899
147.2TF
276FL
291.6TFC
238.6TF
0MWM
128.7TB
162.2TFC
258.8TFC
208.6TFC
0MWL
318.3MGOCONNECTION AT MH 9 O'CLOCK, ACTIVE

Properties (4)

additional_info
SC346167
custom_field_two
1
customer
LACSD
datetime
2017-10-05T22:57:25-07:00