- Date
- 11/01/2017
- W/O
- 669082
- Weather
- Dry
- Operator/Surveyor
- E RUIZ
- Sewer ID
- Z00471
- PipeID
- P06983
- Time
- 10:26 PM
- Certificate
- 123456
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K5122
- Sewer Name
- 05 LOMITA TRUNK
- City
- TORRANCE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 28
- Purpose
- Routine Assessment
- Project
- WO_669082_TV05198_NOV2017
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- 05 1756
- Downstream MH
- 05 1755
- Dir. of Survey
- Downstream
- Length Surveyed
- 428.1 ft.
- Total Length
- 428.1 ft.
- Structural Index
- 2
- Structural Quick
- 3124
- Structural Rating
- 11
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 13
Pipe schematic from manhole 05 1756 to 05 1755 Observation photos (5)

67.3 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

83.4 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

174 ft. - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

178.6 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

247.6 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start