- Date
- 11/02/2017
- W/O
- 669082
- Weather
- Dry
- Operator/Surveyor
- E RUIZ
- Sewer ID
- Z00471
- PipeID
- P06948
- Time
- 1:05 AM
- Certificate
- 123456
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- 5122
- Sewer Name
- 05 LOMITA TRUNK
- City
- TORRANCE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 32
- Purpose
- Routine Assessment
- Project
- WO_669082_TV05198_NOV2017
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- 05 1721
- Downstream MH
- 05 1720
- Dir. of Survey
- Downstream
- Length Surveyed
- 391 ft.
- Total Length
- 391 ft.
- Structural Index
- 4
- Structural Quick
- 4131
- Structural Rating
- 7
- O&M Index
- 4
- O&M Quick
- 4200
- O&M Rating
- 8
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 15
Pipe schematic from manhole 05 1721 to 05 1720 Observation photos (2)

10.2 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

150.1 ft. - Fracture Multiple, from 11 to 12 o'clock, within 8 inches of joint: YES