Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 9, 2016, 11:46 AM
  • 15 0235_15 0234_20160509_050452.mp4

Date
05/09/2016
W/O
568734
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00627
PipeID
P12157
Time
4:46 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3343
Sewer Name
15 SAN JOSE CREEK TRUNK
City
INDUSTRY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
33
Purpose
Routine Assessment
Project
WO_568734_TV15001_MAY2016
Material
Reinforced Concrete Pipe
Shape
Circular
Height
36 in.
Upstream MH
15 0235
Downstream MH
15 0234
Dir. of Survey
Downstream
Length Surveyed
621.8 ft.
Total Length
621.8 ft.
Structural Index
3
Structural Quick
3X2X
Structural Rating
620
O&M Index
2
O&M Quick
2X00
O&M Rating
248
Overall Index
2
Overall Quick
Overall Rating
868
Pipe schematic from manhole 15 0235 to 15 0234
MH: 15 0235MH: 15 0234downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 02352 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start512.2 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"621.8 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish621.8 ft. AMH - Downstream Manhole, Survey Ends - 15 0234621.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish621.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish621.8 ft. MGO - General Observation - COCKROACHES IN MANHOLE

Observation photos (5)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    621.8 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (13)

DistanceCodeObservation
2SSS
621.8SAV
512.2TF
621.8AMH15 0234
0MWL
0MGOCOCKROACHES IN MANHOLE
621.8DAGS
2DAGS
621.8SSS
2SAV
0MWM
621.8MGOCOCKROACHES IN MANHOLE
0AMH15 0235

Properties (5)

additional_info
SC305622
custom_field_two
3
customer
LACSD
datetime
2016-05-09T04:46:14-07:00
sewer_category
GRAVITY