Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 8, 2017, 04:08 PM
  • H 0418_B 0491_1282017_084355.mp4

Date
12/08/2017
W/O
0624598
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00085
PipeID
P08802
Time
8:08 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7579
Sewer Name
B JOINT OUTFALL B - UNIT 2B
City
SOUTH EL MONTE
Loc. details
Woods
Location Code
E
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
27
Purpose
Routine Assessment
Project
20171208SHO_JOINT_OUTFALL_B_UNIT_2B
Material
Reinforced Concrete Pipe
Shape
Circular
Height
57 in.
Upstream MH
H 0418
Downstream MH
B 0491
Dir. of Survey
Downstream
Length Surveyed
45.7 ft.
Total Length
45.7 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
7
Pipe schematic from manhole H 0418 to B 0491
MH: H 0418MH: B 0491downstream0 ft. MWM - Water Mark, 55 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08450 ft. MWL - Water Level, 40 %of cross sectional area9 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start9.8 ft. MGO - General Observation - 65% MAG COAT INTACT43.7 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish45.7 ft. AMH - Downstream Manhole, Survey Ends - 0905

Observation photos (1)

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    9 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
9SAP
43.7SAP
0MWM
0AMH0845
9.8MGO65% MAG COAT INTACT
0MWL
45.7AMH0905

Properties (4)

custom_field_three
AGGREGATE PROJECTING
custom_field_two
3
customer
LACSD
datetime
2017-12-08T08:08:54-08:00