Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 2, 2017, 06:50 AM
  • 18 0594_F 0212 __01112017_235105.mp4

Date
11/01/2017
W/O
668742
Weather
Dry
Operator/Surveyor
JUAN B
Sewer ID
Z00688
PipeID
P14443
Time
11:50 PM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5164
Sewer Name
18 MARQUARDT AVENUE TRUNK
City
CERRITOS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
38
Purpose
Routine Assessment
Project
WO_668742_TV18028_NOV2017
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 0594
Downstream MH
F 0212
Dir. of Survey
Downstream
Length Surveyed
44.7 ft.
Total Length
44.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
3121
O&M Rating
5
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 18 0594 to F 0212
MH: 18 0594MH: F 0212downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 05942 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start42.8 ft. DAE - Deposits Attached Encrustation, 15 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: NO44.7 ft. AMH - Downstream Manhole, Survey Ends - F 021244.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Deposits Attached Encrustation, 15 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: NO

    42.8 ft. - Deposits Attached Encrustation, 15 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: NO

Observations (7)

DistanceCodeObservation
0MWL
44.7AMHF 0212
2DAGS
44.7DAGS
0MWM
42.8DAE
0AMH18 0594

Properties (5)

additional_info
SC350364
custom_field_two
4
customer
LACSD
datetime
2017-11-01T23:50:06-07:00
sewer_category
Gravity