18 0603_18 0602 __31102017_230012.mp4
2.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start
6 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start
135.9 ft. - Roots Fine Barrell, from 10 to 02 o'clock
138.1 ft. - Tap Break-In Defective, at 10 o'clock, -, , within 8 inches of joint: NO, 4" - GREASE
138.1 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 08 to 10 o'clock, , within 8 inches of joint: NO - TAP CONNECTION
160.9 ft. - Roots Fine Connection, from 11 to 01 o'clock
162.5 ft. - Tap Break-In Defective, at 12 o'clock, -, , within 8 inches of joint: NO, 6" - ROOTS
| Distance | Code | Observation |
|---|---|---|
| 149.6 | TBA | — |
| 160.9 | RFC | — |
| 369.6 | TB | — |
| 0 | MWL | — |
| 265.8 | TB | — |
| 135.9 | RFB | — |
| 61.7 | DSC | — |
| 0 | AMH | 18 0603 |
| 0 | MWM | — |
| 411 | AMH | 18 0602 |
| 162.5 | TBD | ROOTS |
| 2.1 | DAGS | — |
| 411 | MGO | ABANDONED CONNECTION AT 3 OC |
| 381.7 | TBA | — |
| 409 | DAGS | — |
| 138.1 | TBD | GREASE |
| 341.3 | DSC | — |
| 6 | DAE | — |
| 409 | DAE | — |
| 138.1 | DAGS | TAP CONNECTION |