- Date
- 10/31/2017
- W/O
- 668742
- Weather
- Dry
- Operator/Surveyor
- JUAN B
- Sewer ID
- Z00688
- PipeID
- P14452
- Time
- 11:23 PM
- Certificate
- U-715-07000770
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K5163
- Sewer Name
- 18 MARQUARDT AVENUE TRUNK
- City
- SANTA FE SPRINGS
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 35
- Purpose
- Routine Assessment
- Project
- WO_668742_TV18028_NOV2017
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 24 in.
- Width
- 24 in.
- Upstream MH
- 18 0602
- Downstream MH
- 18 0601
- Dir. of Survey
- Downstream
- Length Surveyed
- 290.1 ft.
- Total Length
- 290.1 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 2
- O&M Quick
- 2200
- O&M Rating
- 4
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 4
Pipe schematic from manhole 18 0602 to 18 0601 Observation photos (2)

2.2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

89.1 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start