Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 28, 2016, 06:35 AM
  • 32 0266_32 0265 _10272016_233527.mp4

Date
10/27/2016
W/O
579953
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00914
PipeID
P23971
Time
11:35 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3796
Sewer Name
32 DISTRICT #32 MAIN RELIEF TRUNK
City
SANTA CLARITA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
06
Purpose
Routine Assessment
Project
WO_579953_TV32037_JULY2016
Material
RGRCP
Shape
Circular
Height
48 in.
Width
48 in.
Upstream MH
32 0266
Downstream MH
32 0265
Dir. of Survey
Downstream
Length Surveyed
251.5 ft.
Total Length
251.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2I00
O&M Rating
98
Overall Index
2
Overall Quick
Overall Rating
98
Pipe schematic from manhole 32 0266 to 32 0265
MH: 32 0266MH: 32 0265downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 32 02660 ft. MWL - Water Level, 15 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start248.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish251.5 ft. AMH - Downstream Manhole, Survey Ends - 32 0265

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (6)

DistanceCodeObservation
0MWM
251.5AMH32 0265
248.6DAGS
0AMH32 0266
2DAGS
0MWL

Properties (6)

additional_info
SC306334
custom_field_two
4
customer
LACSD
datetime
2016-10-27T23:35:08-07:00
sewer_category
Gravity
year_laid
37313