Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 11, 2017, 09:43 AM
  • 04 0061_04 0060 _10112017_024340.mp4

Date
10/11/2017
W/O
663608
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00412
PipeID
P11797
Time
2:43 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4747
Sewer Name
04 LA CIENEGA BOULEVARD TRUNK
City
WEST HOLLYWOOD
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 04
Page No.
01
Purpose
Routine Assessment
Project
WO_663608_TV04007_OCT2017
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
04 0060
Downstream MH
04 0061
Dir. of Survey
Upstream
Length Surveyed
95.3 ft.
Total Length
95.3 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 04 0060 to 04 0061
MH: 04 0060MH: 04 0061upstream0 ft. AMH - Upstream Manhole, Survey Ends - 04 00610 ft. MGO - General Observation - COCKROACHES IN MANHOLE53.8 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES95.3 ft. MWL - Water Level, 5 %of cross sectional area95.3 ft. AMH - Downstream Manhole, Survey Begins - 04 0060

Observation photos (1)

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    41.5 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (5)

DistanceCodeObservation
95.3AMH04 0061
95.3MGOCOCKROACHES IN MANHOLE
0MWL
41.5CM
0AMH04 0060

Properties (5)

additional_info
SC346062
custom_field_two
4
customer
LACSD
datetime
2017-10-11T02:43:16-07:00
sewer_category
Gravity