- Date
- 10/11/2017
- W/O
- 663287
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00819
- PipeID
- P17387
- Time
- 11:30 PM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K5016
- Sewer Name
- 22 LORAINE TRUNK
- City
- GLENDORA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 13
- Purpose
- Routine Assessment
- Project
- WO_663287_TV22109_OCT2017
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 22 1018
- Downstream MH
- 22 1017
- Dir. of Survey
- Downstream
- Length Surveyed
- 442.4 ft.
- Total Length
- 442.4 ft.
- Structural Index
- 3
- Structural Quick
- 3Q00
- Structural Rating
- 264
- O&M Index
- 3
- O&M Quick
- 3100
- O&M Rating
- 3
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 267
Pipe schematic from manhole 22 1018 to 22 1017 Observation photos (2)

4.6 ft. - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

128.4 ft. - Roots Medium Joint, from 04 to 10 o'clock, 15 %, within 8 inches of joint: YESR