Section#5_J 0233_J 0232__1262017__G6880.mp4
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE
2 ft. - General Observation - MAG COAT 70% START 8:00 TO 4:00
9.4 ft. - Surface Aggregate Visible, from 02 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC
25 ft. - Surface Aggregate Visible, from 02 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG SPORATIC
33.4 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE
152.9 ft. - Surface Reinforcement Visible, from 09 to 10 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
182.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG
225.5 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - PEELING CONCRETE
232.4 ft. - Surface Reinforcement Visible, from 09 to 10 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
234.5 ft. - Surface Aggregate Projecting, from 09 to 11 o'clock, within 8 inches of joint: NO - SEVERE AGG
236.8 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
249 ft. - General Observation - THICK JOINT
257 ft. - General Observation - MAG COAT 40% START
282.2 ft. - Surface Reinforcement Visible, from 01 to 02 o'clock, within 8 inches of joint: YES - CIRCUM REBAR
293.2 ft. - Surface Reinforcement Visible, from 10 to 11 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
| Distance | Code | Observation |
|---|---|---|
| 152.9 | SRV | CIRCUM REBAR |
| 0 | MWM | — |
| 2 | SSS | BLISTERING PEELING CONCRETE |
| 236.8 | SAV | SEVERE AGG |
| 0 | MWL | — |
| 234.5 | SAP | SEVERE AGG |
| 0 | MGO | MH CONN OPEN 9:00 |
| 182.1 | SAV | SEVERE AGG |
| 370.2 | SAV | SEVERE AGG SPORATIC |
| 178.4 | SAV | SEVERE AGG SPORATIC |
| 370.2 | DSGV | — |
| 257 | MGO | MAG COAT 40% START |
| 370.8 | AMH | 5:25AM |
| 9.4 | SAV | SEVERE AGG SPORATIC |
| 225.5 | SSS | PEELING CONCRETE |
| 370.2 | SSS | BLISTERING PEELING CONCRETE |
| 249 | MGO | THICK JOINT |
| 247.2 | DSGV | — |
| 0 | AMH | 4:45AM |
| 25 | SAV | SEVERE AGG SPORATIC |
| 282.2 | SRV | CIRCUM REBAR |
| 370.2 | MGO | MH CONN 9:00 ACTIVE |
| 232.4 | SRV | CIRCUM REBAR |
| 2 | MGO | MAG COAT 70% START 8:00 TO 4:00 |
| 0 | MGO | MH CONN 3:00 STUB |
| 33.4 | SSS | PEELING CONCRETE |
| 293.2 | SRV | CIRCUM REBAR |