- Date
- 10/05/2017
- W/O
- 663250
- Weather
- Dry
- Operator/Surveyor
- ERU
- Sewer ID
- Z00025
- PipeID
- P00530
- Time
- 12:58 PM
- Certificate
- 123456
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K4290
- Sewer Name
- 08 216TH STREET RELOCATION TRUNK
- City
- CARSON
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 13
- Purpose
- Routine Assessment
- Project
- WO_663250_TV08101_OCT2017
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 48 in.
- Width
- 48 in.
- Upstream MH
- 08 0596
- Downstream MH
- D 0008
- Dir. of Survey
- Downstream
- Length Surveyed
- 713.1 ft.
- Total Length
- 713.1 ft.
- Structural Index
- 4
- Structural Quick
- 5231
- Structural Rating
- 13
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 13
Pipe schematic from manhole 08 0596 to D 0008 Observation photos (3)

2 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

494.3 ft. - Surface Reinforcement Corroded, from 11 to 03 o'clock, within 8 inches of joint: YES