- Date
- 09/21/2017
- W/O
- 657807
- Weather
- Dry
- Operator/Surveyor
- CORTEZ ESTEBAN
- Sewer ID
- Z00639
- PipeID
- P13056
- Time
- 1:01 AM
- Certificate
- U-209-8148
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K4932
- Sewer Name
- 16 ALLEN AVENUE TRUNK, SECTS 1,2,&4
- City
- SAN GABRIEL
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 02
- Purpose
- Routine Assessment
- Project
- WO_657807_TV16113_SEP2017
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 16 in.
- Width
- 16 in.
- Upstream MH
- 16 0042
- Downstream MH
- 16 0043
- Dir. of Survey
- Upstream
- Length Surveyed
- 324.9 ft.
- Total Length
- 324.9 ft.
- Structural Index
- 3
- Structural Quick
- 3222
- Structural Rating
- 10
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 12
Pipe schematic from manhole 16 0042 to 16 0043 Observation photos (5)

50 ft. - Crack Multiple, from 10 to 01 o'clock, within 8 inches of joint: YES

62 ft. - Tap Break-In Intruding, at 02 o'clock, -, -, within 8 inches of joint: YES, 6", 1"

157.7 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

240.9 ft. - Crack Multiple, from 11 to 02 o'clock, within 8 inches of joint: YES