Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 10, 2015, 06:48 AM
  • 16 0602_16 0601_20151209_232147.mp4

Date
12/09/2015
W/O
531059
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00664
PipeID
P13652
Time
10:48 PM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3006
Sewer Name
16 PASADENA EAST-WEST INTERCEPTOR TRUNK
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
10
Purpose
Routine Assessment
Project
WO_531059_TV16030_OCT2015
Material
Reinforced Concrete Pipe
Shape
Circular
Height
42 in.
Upstream MH
16 0602
Downstream MH
16 0601
Dir. of Survey
Downstream
Length Surveyed
806.9 ft.
Total Length
806.9 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
2
O&M Quick
2212
O&M Rating
6
Overall Index
2
Overall Quick
Overall Rating
12
Pipe schematic from manhole 16 0602 to 16 0601
MH: 16 0602MH: 16 0601downstream0 ft. VC - Vermin Cockroach0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK ACTIVE0 ft. AMH - Upstream Manhole, Survey Begins - 16 06022.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.3 ft. MGO - General Observation - MAGNEZIUM H.O. START2.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start59.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6100.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"148.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"205.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"260.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"300.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"349.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"406 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"445.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"501.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"550.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"605.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"694.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"776.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"801.9 ft. MGO - General Observation - MAGNEZIUM H.O. FINISH801.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish801.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish806.9 ft. AMH - Downstream Manhole, Survey Ends - 16 0601806.9 ft. VC - Vermin Cockroach806.9 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK ACTIVE

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.3 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (28)

DistanceCodeObservation
445.5TFA
550.2TF
2.3SAV
801.9MGOMAGNEZIUM H.O. FINISH
806.9AMH16 0601
406TFA
349.5TFA
0VC
2.3MGOMAGNEZIUM H.O. START
148.5TFA
801.9SAV
801.9DAGS
260.9TFA
501.5TFA
0MWL
694.5TFA
0MWM
59.9TFA
300.3TFA
806.9VC
2.3DAGS
776.7TFC
806.9MGOLATERAL AT MH 9 OCLOCK ACTIVE
605.7TF
100.5TFA
0MGOLATERAL AT MH 9 OCLOCK ACTIVE
205.3TFA
0AMH16 0602

Properties (5)

additional_info
SC205698
custom_field_two
3
customer
LACSD
datetime
2015-12-09T22:48:41-08:00
sewer_category