Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 6, 2017, 10:15 AM
  • 05 0888_05 0886 _06102017_031555.mp4

Date
10/06/2017
W/O
663034
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00512
PipeID
P07572
Time
3:15 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5008
Sewer Name
05 RAYMOND AVENUE TRUNK
City
HAWTHRONE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
13
Purpose
Routine Assessment
Project
WO_663034_TV05096_OCT2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
05 0888
Downstream MH
05 0886
Dir. of Survey
Downstream
Length Surveyed
307 ft.
Total Length
307.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 05 0888 to 05 0886
MH: 05 0888MH: 05 0886downstream0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK CAPPED0 ft. MWM - Water Mark, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 08880 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK, ACTIVE0 ft. MWL - Water Level, 5 %of cross sectional area45.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"73.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"93.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"95.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"121.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"136.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"151.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"174 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"176.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"202.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"224.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"227.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"252.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"273.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"275.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"307.1 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK, ACTIVE307.1 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK, ACTIVE307.1 ft. AMH - Downstream Manhole, Survey Ends - 05 0886

Observations (23)

DistanceCodeObservation
252.9TFC
273.2TFC
227.2TF
95.9TF
0MGOCONNECTION AT MH 3 O'CLOCK CAPPED
275.7TF
73.5TFC
174TFC
0MWM
176.8TF
0AMH05 0888
202.1TFC
307.1MGOCONNECTION AT MH 9 O'CLOCK, ACTIVE
224.8TFC
45.5TFC
0MGOCONNECTION AT MH 9 O'CLOCK, ACTIVE
0MWL
307.1MGOCONNECTION AT MH 3 O'CLOCK, ACTIVE
121.5TF
307.1AMH05 0886
151.7TFC
136.4TFC
93.3TFC

Properties (4)

additional_info
SC346168
custom_field_two
4
customer
LACSD
datetime
2017-10-06T03:15:16-07:00