Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 6, 2017, 07:38 AM
  • 05 0894_05 0893 _06102017_003903.mp4

Date
10/06/2017
W/O
663034
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00512
PipeID
P06124
Time
12:38 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5008
Sewer Name
05 RAYMOND AVENUE TRUNK
City
HAWTHRONE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
13
Purpose
Routine Assessment
Project
WO_663034_TV05096_OCT2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
05 0894
Downstream MH
05 0893
Dir. of Survey
Downstream
Length Surveyed
106.3 ft.
Total Length
106.3 ft.
Structural Index
3
Structural Quick
3B00
Structural Rating
45
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
49
Pipe schematic from manhole 05 0894 to 05 0893
MH: 05 0894MH: 05 0893downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 08940 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK, ACTIVE0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK CAPPED0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area2.6 ft. CM - Crack Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES5.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start67.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"70 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"73.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish77.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"105.4 ft. TSI - Tap Saddle Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 2"106.3 ft. MSA - Survey Abandoned - CAM BLKD BY INTRUDING LATERAL

Observation photos (4)

  • Crack Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES

    2.6 ft. - Crack Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Saddle Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 2"

    105.4 ft. - Tap Saddle Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 2"

  • Survey Abandoned - CAM BLKD BY INTRUDING LATERAL

    106.3 ft. - Survey Abandoned - CAM BLKD BY INTRUDING LATERAL

Observations (13)

DistanceCodeObservation
0AMH05 0894
0MGOCONNECTION AT MH 9 O'CLOCK, ACTIVE
2.6CM
5.6CM
77.7TF
67.9TF
105.4TSI
70TF
0MGOCONNECTION AT MH 3 O'CLOCK CAPPED
0MWM
106.3MSACAM BLKD BY INTRUDING LATERAL
0MWL
73.4CM

Properties (4)

additional_info
SC346168
custom_field_two
5
customer
LACSD
datetime
2017-10-06T00:38:54-07:00