Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 2, 2017, 09:55 AM
  • 16 0269_16 0268 _02102017_025530.mpg

Date
10/02/2017
W/O
658236
Weather
Dry
Operator/Surveyor
CORTEZ ESTEBAN
Sewer ID
Z00653
PipeID
P13322
Time
2:55 AM
Certificate
U-209-8148
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4948
Sewer Name
16 CHAPEL AVENUE TRUNK, SECTION 2
City
SAN MARINO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
17
Purpose
Routine Assessment
Project
WO_658236_TV16018_SEP2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
16 0268
Downstream MH
16 0269
Dir. of Survey
Upstream
Length Surveyed
148.1 ft.
Total Length
148.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 16 0268 to 16 0269
MH: 16 0268MH: 16 0269upstream0 ft. MSA - Survey Abandoned - A/S COMPETED REVERSAL INSPECTION20.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"35 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"37.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"64.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"65.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"79.4 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"98.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"119.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"124.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"147.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"148.1 ft. AMH - Downstream Manhole, Survey Begins - 16 0268148.1 ft. MWL - Water Level, 5 %of cross sectional area148.1 ft. MGO - Reversal Inspection148.1 ft. MWM - Water Mark, 15 %of cross sectional area

Observation photos (1)

  • Survey Abandoned - A/S COMPETED REVERSAL INSPECTION

    148.1 ft. - Survey Abandoned - A/S COMPETED REVERSAL INSPECTION

Observations (15)

DistanceCodeObservation
0AMH16 0268
68.7TFA
148.1MSAA/S COMPETED REVERSAL INSPECTION
49.9TFC
28.8TFA
84TFA
110.5TFC
82.3TFA
1TFA
0MWL
113.1TFC
0MGO
23.3TFC
0MWM
127.8TFC

Properties (4)

additional_info
SC345856
custom_field_two
4
customer
LACSD
datetime
2017-10-02T02:55:18-07:00