Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 28, 2017, 09:30 AM
  • 16 0553_16 0552 _28092017_023130.mp4

Date
09/28/2017
W/O
663269
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00659
PipeID
P13604
Time
2:30 AM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4280
Sewer Name
16 LAMANDA PARK TRUNK
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
15
Purpose
Routine Assessment
Project
WO_663269_TV16077_OCT2017
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
16 0553
Downstream MH
16 0552
Dir. of Survey
Downstream
Length Surveyed
101.8 ft.
Total Length
101.8 ft.
Structural Index
3
Structural Quick
3C00
Structural Rating
57
O&M Index
2
O&M Quick
2C11
O&M Rating
39
Overall Index
2
Overall Quick
Overall Rating
96
Pipe schematic from manhole 16 0553 to 16 0552
MH: 16 0553MH: 16 0552downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 16 05533.1 ft. MGO - General Observation - MAG COAT START3.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start3.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start36.8 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"52.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"85.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"89 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"99.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish99.8 ft. MGO - General Observation - MAG COAT FINISH99.8 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish101.7 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK ACTIVE101.7 ft. VC - Vermin Cockroach101.8 ft. AMH - Downstream Manhole, Survey Ends - 16 0552

Observation photos (8)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    3.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"

    36.8 ft. - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"

  • Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"

    52.6 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"

  • Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"

    85.4 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"

  • Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"

    89 ft. - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Finish

    99.7 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

    99.8 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observations (16)

DistanceCodeObservation
52.6TF
85.4TFC
3.1MGOMAG COAT START
99.8MGOMAG COAT FINISH
99.8SAV
89TBA
3.1SAV
101.7MGOCONNECTION AT MH 9 O'CLOCK ACTIVE
36.8TBA
3.1DAGS
0MWM
101.7VC
0MWL
101.8AMH16 0552
0AMH16 0553
99.7DAGS

Properties (5)

additional_info
SC352126
custom_field_two
3
customer
LACSD
datetime
2017-09-28T02:30:17-07:00
sewer_category
Gravity